Industrial Battery Chargers Manufacturers & Suppliers in Hyderabad


Industrial Battery Chargers:

industrial-battery-chargers

Features


  • Modular construction
  • Input isolation transformer
  • 2-Pulse (1-Phase) / 6-Pulse (3-Phase) thyristor rectifier bridge
  • Fully digital microcontroller based control
  • Soft start
  • Automatic boost mode selection according to boost / float current set value
  • Adjustable DC voltage & current settings
  • Smoothing chokes & capacitor bank to reduce ripple
  • Isolated current input to controller from hall effect current module
  • Electronic battery current limit
  • Battery reverse polarity protection
  • Parallel redundant operation
  • In-built DC distribution board
  • Good dynamic response

  • Options


  • 12-Pulse thyristor rectifier bridge
  • Additional reduction of output ripple below 2% RMS
  • AC surge protection
  • Fuse failure protection
  • Annunciator based annunciation systems
  • Silicon dropper diodes for load output regulation
  • Deep discharge battery isolation contactor
  • Digital meters
  • RS-485 Modbus interface
  • Remote control software
  • DC Earth fault and additional alarms, meters and potential-free contacts
  • Special colour and higher protection degree
  • Temperature compensation for battery
  • Top cable entry

  • Applications


  • Power plants
  • Sub stations
  • Industries
  • Railways
  • Offshore projects
  • Petro-chemical
  • Oil and gas pipeline systems
  •         
  • Technical Specification

    Nominal VoltageVDC12 - 24 - 30 - 36 - 48 - 110 - 220
    Input AC voltageVAC230 +/- 10%; 2-wire, 380/400/415 +/- 10%; 3/4-wire
    Input frequencyHz50 +/- 5%
    DC output currentAup to 100A
    DC voltage accuracy%+/- 1% under all operating conditions
    Output ripple%<2% RMS without battery connected (lower available on request)
    Efficiency%70 - 90% typical at full load
    Operating conditionsdeg C-10 to 40 Deg C (up to 50 Deg C on request)
    RH<=95% humidity (non-condensing)
    m<= 1000 m above sea level
    VentilationNatural convection
    Cabinet ingress protectionIP20 (upto IP43 on request)
    ColourRAL 7032/7035 (other colours available on request)
    Standard instrumentsOutput: DC voltmeter, DC ammeter
    Battery: Centre zero ammeter
    Input: AC Voltmeter, AC Ammeter (optional)
    Standard protectionsThyristor protection fuse, DC over voltage cut-off, Electronic current limitation, battery under voltage, AC unhealthy, phase sequence, phase failure, AC & DC circuit breakers, charger over load/load limiter
    Alarms & status indicationAC failure, DC over voltage, DC over current, Battery under voltage, float mode, boost mode, AC on, DC on, charger failure, AC unhealthy
    Charging characteristicsConstant current / Constant voltage & current limit
    Charger topologiesTrickle / Float cum Boost / Float & Boost / Float & Float cum Boost / Dual Float cum Boost
    Quality environmentISO 9001:2015

    General

  • The protection of electrical load against power failure is often carried out by battery backed up DC power supplies, providing electrical energy to important loads during mains supply, as well as during mains failure.
  • Battery backed up DC power supplies have, over several decades proved extremely reliable and very economical power supplies. The reliability of a battery backed up DC power supply is defined by the quality of the battery used, as well as the reliable control & operation of the rectifier.
  • Our range of battery chargers uses latest digital microcontroller based technology for precise control and also offers full range of options for meeting most stringent requirements.


  • More Details: